In short
- The work mode decides what happens to surplus solar: sold, or held back so that the house and the battery use it.
- The time-of-use table adds rules per time slot: how far the battery may discharge, and whether the grid may charge it.
- Settings are only half the story: a day of real curves shows whether the inverter does what you meant.
Two installations with the same Deye inverter and the same panels can behave very differently. The difference usually sits in two screens of the settings menu: the work mode and the time-of-use table. Installers set them once, often in a hurry, and few owners look at them again.
The three work modes
| Mode | What it does | Typical use |
|---|---|---|
| Selling First | Solar covers the house, then the surplus is exported to the grid, up to the export limit you set. | A good feed-in tariff. |
| Zero Export To Load | Only the loads on the inverter’s load (backup) output are covered; nothing goes back to the grid. | Export not allowed, loads wired behind the inverter. |
| Zero Export To CT | A current clamp on the grid supply lets the inverter cover the whole house without exporting. | Export not allowed or not paid, whole house to cover. |
The exact names vary a little between firmware versions and models; your installer’s manual is the reference.
Time of use: the timetable
With time of use on, the day is cut into slots, usually six. For each slot you set a power, a battery level and whether the grid may charge the battery. Two patterns are common: keep the battery above a reserve during the day so it lasts the evening, and allow grid charging only during off-peak hours. A slot set to a high level by mistake is the classic reason why a battery stays full while the house buys power in the evening.
Checking it on a real day
Settings tell you the intention. The curves tell you what happened. Deye Monitor reads the inverter on its RS485 port and draws the day: solar, battery, grid and house. Three things are worth a look:
- At midday, with a full battery: in Selling First you should see export; in a zero-export mode, the solar curve flattens instead.
- In the evening, the battery should carry the house down to the reserve you set, not stop much earlier.
- At night, grid charging should only appear in the slots where you allowed it.
The box only reads: it never changes a mode or a slot. You change settings on the inverter, then compare the next day with the previous one.
A rule of thumb
If export is paid little, let the house and the battery use the sun first, and spend the surplus on things that can wait for it: a water heater, a washing machine, a car. That last part is where Home Assistant helps, with automations driven by the surplus the box sees.
Common questions
Does Deye Monitor change the work mode?
No. It only reads the inverter. Modes and time slots are changed on the inverter or in the tools your installer uses.
Why does my battery stay full in the evening?
Often a time-of-use slot keeps a high battery level during the evening. Check the level set for each slot and compare with the evening curve.
Do I need a CT clamp for zero export?
For Zero Export To CT, yes: the clamp on the grid supply tells the inverter how much the whole house draws.