In short
- Most Deye alarms come from a short list: grid, battery, communication, overload and heat.
- The code tells you where to look; the values just before it tell you why.
- Write down the time and the battery and load figures when a code appears: your installer will ask.
The names below are those of the Deye manual for the SG hybrid range. Wording changes a little between firmware versions and models, so treat this as a guide to where to look, and keep the manual of your exact model close by.
F13: working mode change
Often seen right after someone changed the work mode, the grid standard or a battery setting. In most cases it clears by itself within a minute. If it returns every day without anyone touching the settings, note when it happens: a pattern at the same hour points to a timed setting.
F18: AC overcurrent (hardware)
The inverter saw a current peak on the AC side larger than it can handle. Typical causes are a heavy motor start on the load output, a short circuit, or simply too much load at once. Check what started at that moment: a pump, a compressor, an oven.
F24: DC insulation impedance
The inverter measured a leak between the PV strings and earth. Morning dew and rain are classic triggers, which is why the code sometimes vanishes once the panels dry. If it persists in dry weather, a cable or connector on the roof needs a qualified check.
F35: no AC grid
The grid is gone: a power cut, a tripped breaker on the grid side, or a loose grid connection. During an outage this code is expected, and your backup output should keep running if the battery allows it.
F56: DC bus voltage too low
Usually the battery side. The battery reached its low limit, the BMS disconnected it, or the battery breaker is off. Look at the battery charge and voltage just before the fault: a sudden drop to zero means the BMS or a breaker opened, a slow slide means the battery simply ran down.
F58: BMS communication fault
The inverter lost contact with the battery BMS over CAN or RS485. Check the communication cable, the battery protocol selected in the inverter, and that the master battery is switched on. A cable moved during cleaning is a frequent culprit.
F64: heat sink temperature high
The inverter is too hot. A closed cupboard, a sunny wall in summer or blocked air vents are the usual reasons. The inverter often reduces power before it stops, so a slow decline in output on hot afternoons is an early sign.
Keep the context, not only the code
A code on the screen is a snapshot. What helps is the minute before it: load, battery voltage, PV power, temperature. Deye Monitor keeps these values every few seconds on the box and in the free Cloud, so you can scroll back to the moment of the alarm instead of guessing.
Common questions
Can I reset a Deye fault code myself?
Most codes clear on their own once the cause has gone. If a code keeps coming back, find the cause rather than restarting the inverter again and again.
Is F35 a problem with my inverter?
Rarely. F35 means the inverter sees no grid. Check your supply and the breaker between the grid and the inverter first.
Does Deye Monitor change inverter settings to clear a fault?
No. It only reads the inverter. It shows the alarm and the values around it; it never writes a setting.